VITROCELL® TEM Grid holders for dose determination of airborne particles during in vitro Exposure at the air / liquid interface
Size, shape and distribution of particles are analysed at significantly higher resolution than with usual light microscopes
(PresseBox) - .
Background
The assessment of toxicological effects of airborne particles to the human organism is of major importance in disease research. The presence of nano and ultrafine particles can be found both in indoor and outdoor atmospheres which include workplaces and living areas.
Over the last years, the degree of contribution to diseases of such particles is analyzed ever more frequent by the use of in vitro methods. The required equipment for these studies consisting of aerosol generation and exposure systems are nowadays developed more and more to proven levels. Here the exposure of lung cells to particles at the air/liquid interface is the prime choice over submerse exposure conditions as interaction of particles with cell culture media is avoided. So the air/liquid interface is a physiologic relevant exposure technique (picture 1).
Furthermore, dose determination under submerse conditions, thus which amount of the substance has reached the cells, is extremely difficult.
For over 10 years, VITROCELL
The subsequent required information is related to size, shape and distribution of the particles at the level of the cell culture insert. For this analysis Transmission Electron Microscopy (TEM) is a proven method. Here a beam of electrons is transmitted through a specimen to form an image. The resolution is significantly higher than of usual light microscopes.
For this purpose, particles are captured on TEM grid sample carriers (picture 2) and then transferred to the TEM microscope. Due to the small size of the grids, placement in cell culture inserts is extremely difficult and it is almost impossible to position them always at the same location.
Solution
For application inside the Vitrocell
The TEM grid holders can be equipped with standard sample carriers to analyse number, morphology and distribution of deposited particles. The grids are located on the same level as the cells during a regular exposure. Furthermore, the grids can be fixed on different radii on the insert surface to evaluate spatial distribution. The fixation also prevents the grid from any motion on the insert during
the experiment. The VITROCELL
Results
Picture 3 shows images of particles deposited on sample grids inside the VITROCELL
A recent publication in Nature Scientific Reports (M
References
Nature Scientific Reports, volume 10, Article number: 8401 (2020)
Published: 21 May 2020
Open Access:
?A novel TEM grid sampler for airborne particles to measure the cell culture surface dose?
Sonja M& Dieter Stapf
For publications please visit the publication area of our website: www.vitrocell.com/...
VITROCELL
VITROCELL
Themen in dieser Pressemitteilung:
Unternehmensinformation / Kurzprofil:
VITROCELL® Systems GmbH - Advanced in vitro exposure systemsVITROCELL® exclusively concentrates on the developing, producing, installing, training and servicing of advanced in vitro exposure systems.
Datum: 25.06.2020 - 06:06 Uhr
Sprache: Deutsch
News-ID 1559056
Anzahl Zeichen: 2634
contact information:
Contact person:
Town:
Waldkirch
Phone:
Kategorie:
Electronics & Semiconductors
Typ of Press Release:
type of sending:
Date of sending:
Anmerkungen:
Diese Pressemitteilung wurde bisher 900 mal aufgerufen.
Die Pressemitteilung mit dem Titel:
"VITROCELL® TEM Grid holders for dose determination of airborne particles during in vitro Exposure at the air / liquid interface
"
steht unter der journalistisch-redaktionellen Verantwortung von
VITROCELL Systems GmbH (Nachricht senden)
Beachten Sie bitte die weiteren Informationen zum Haftungsauschluß (gemäß TMG - TeleMedianGesetz) und dem Datenschutz (gemäß der DSGVO).