businesspress24.com - Perforated heat conducting profile enables excellent sound absorption and new opportunities for Lind
 

Perforated heat conducting profile enables excellent sound absorption and new opportunities for Lindner Plafotherm® Heated and Chilled Metal Ceilings

ID: 1243180

The latest product range"Acoustics"offers expanded opportunities for the product line Plafotherm® Heated and Chilled Metal Ceilings

(firmenpresse) - The latest product range "Acoustics" offers expanded opportunities for the product line Plafotherm® Heated and Chilled Metal Ceilings.

Due to the product name, the application of the new heating and cooling technology can easily be named. In contrast to the non-perforated heat conducting profile of "Plafotherm® B 100", the heated and chilled ceiling "Plafotherm® B 100 Acoustics" uses the new, perforated heat conducting profile.

Just like inactive metal ceiling systems, the acoustic transparent heat conducting profiles provide excellent sound absorption coefficients - both with and without mineral wool inlay. . Thus, e.g. a sound absorption coefficient w of 0.70 without mineral wool and even 0.80 with mineral wool will be achieved with a perforation of 20 % open area and complete distribution with heat conducting profiles. When using the perforated heat conducting profile, a cooling loss of 15 % results. However, comparing the new development with the usual heating and cooling technology with the same perforation of the ceiling panels, a 60 % higher sound absorption can be realised.

The flexible production of Lindner enables the realisation of you specific project demands. Thanks to the high vertical range of manufacture, we can optimally customise the heating and cooling coil to every ceiling panel format with or without cut-out. Every heating and cooling coil is manufactured object-related and customised. Cut-outs - e.g. for luminaires, beamer lifts or other fixtures - are individually observed at the coil manufacturing. Thus, the maximum distribution of the area resp. the maximum heating and cooling capacity can be carried into the room.

The manufacturing of our heat conducting profiles shows that Lindner Group pays special attention to an environmentally friendly production. There is little wasted material due to the order-related and customised production of the cold-rolled heat conducting profiles in our plant in Arnstorf. Furthermore, Lindner Heated and Chilled Metal Ceiling elements with powder coating, acoustic tissue and thermally conductive heating and cooling coils are classified as toxicological harmless. Tests proved that the content of VOC - volatile organic compounds - is far below the evaluation limit. Using the new heating and cooling technology, you are improving the acoustics in your room while supporting us with the environmental protection.





For more information regarding Lindner Heated and Chilled Metal Ceilings please visit our homepage www.Lindner-Group.com


Themen in dieser Pressemitteilung:


Unternehmensinformation / Kurzprofil:

Lindner - Bauen mit neuen Lösungen.



Die Lindner Group ist Europas führender Spezialist für Innenausbau, Fassadenbau und Isoliertechnik.



Gegründet 1965 im niederbayerischen Arnstorf, erbringen wir über ein internationales Netzwerk mit einer heute einzigartigen Leistungskette "Konzepte-Produkte-Service" komplette, maßgeschneiderte Baulösungen für unsere Kunden.



Als verantwortungsbewusstes, innovatives Familienunternehmen legen wir besonderen Wert auf eine nachhaltige Entwicklung und setzen in der Produktion und auf den Baustellen weltweit auf zukunftsorientiertes Energiemanagement und angewandten Umweltschutz.



Leseranfragen:



PresseKontakt / Agentur:

Lindner Group
Ingo Bofinger
Bahnhofstr. 29
94424 Arnstorf
Ingo.Bofinger(at)Lindner-Group.com
+49 (0)8723/20-27 58
http://www.Lindner-Group.com



drucken  als PDF  an Freund senden  Innovation in 3D - YOUplikate by EuroMold
DSIR recognises Kochi R&D Center of V-Guard Industries
Bereitgestellt von Benutzer: Adenion
Datum: 08.07.2013 - 08:30 Uhr
Sprache: Deutsch
News-ID 1243180
Anzahl Zeichen: 0

contact information:
Contact person: Wolfram Aichner
Town:

Arnstorf


Phone: +49 (0)8723/20-32 12

Kategorie:

Electronics & Semiconductors


Anmerkungen:


Diese Pressemitteilung wurde bisher 228 mal aufgerufen.


Die Pressemitteilung mit dem Titel:
"Perforated heat conducting profile enables excellent sound absorption and new opportunities for Lindner Plafotherm® Heated and Chilled Metal Ceilings
"
steht unter der journalistisch-redaktionellen Verantwortung von

Lindner Group (Nachricht senden)

Beachten Sie bitte die weiteren Informationen zum Haftungsauschluß (gemäß TMG - TeleMedianGesetz) und dem Datenschutz (gemäß der DSGVO).


Alle Meldungen von Lindner Group



 

Who is online

All members: 10 563
Register today: 0
Register yesterday: 2
Members online: 0
Guests online: 63


Don't have an account yet? You can create one. As registered user you have some advantages like theme manager, comments configuration and post comments with your name.