Application-friendly renovation render with expanded glass
Effective renovation of humid and salt damaged walls
(PresseBox) - In renovation renders with Poraver
Efflorescence in construction
Renovation renders are used for the renovation of humid walls. The moisture causes efflorescence and salt crystallization, which can turn in structural damages. Both existing buildings and new buildings are affected. The reason for the efflorescence can be for example structural deficiencies or unsealed basement walls. The renovation of those buildings needs at first a proper sealing of the leakage and a removal of the salt in the walls without generating further damages. One possibility is the usage of renovation renders.
The problem of efflorescence can have many reasons and manifestations. Efflorescence occur on renders, pavements, cement blocks, bricks etc. Most commonly efflorescence is formed by carbonation of lime (Ca(OH)2) or salts (sodium chloride, sulfate or nitrate). These materials can be either part of the formulation, the hardening reaction or can be absorbed from the environment in combination with leakage. In addition to the optical problems on a render surface, such as the mentioned efflorescence or hygroscopic spots, the continuous crystallization of salt will lead to a delamination of paint, deposits and the gradual destruction of the render caused by the increased stress of the building material structure during frost.
Renovation of efflorescence
In the cases of efflorescence caused by the carbonation of lime Ca(OH)2 the issue can be solved by adding pozzolanic co-binders or the usage of aluminate cements to catch or even not to form the portlandite.
Efflorescence based on salt disposal in combination with a leakage need a different approach. A simple sealing with a water proofing layer of the wet area and renewal of the render is not suitable to solve the problem as water will just rise higher due to the capillary effect and the same damage will occur in the next level. The renovation of salt contaminated brick work/walls has to be done in 2 steps:
Stopping of water supply
Drying out of the wall and allow a crystallization of the salt without damaging the new render layer.
Requirements and formulation of renovation renders
Mortar systems that support this out drying and crystallization are described in ?WTA Merkblatt 2-9-04/D? in addition to EN 998 ?Specification for mortar for masonry. Rendering and plastering mortar?. The special design of the render formulation will allow the water to evaporate easily and the salt will crystalize in the pore system of the renovation render without damaging the binder matrix. To achieve its special properties renovation renders have to fulfill the following requirements:
Air content:> 25 vol.-%
Dry density:< 1.400 kg/m3
Capillary water absorption (24h, disc):> 0.3 kg/m2
Water intake:< 5 mm
Water vapor coefficient (m-value): < 12
Porosity: > 40 vol.-%
Salt resistance: passed
A stable pore volume and high salt storage capacity with Poraver
One challenge of the formulation is to achieve a high volume and stable pore system and a balanced hydrophobicity. The pores have to be stable during mixing and application but also need to be relatively large in size to stop the capillarity and to have enough space for the salt to crystallize. Typically pores in renders are ?generated? by using air entraining agents. The disadvantage of air entraining agents is their dependency on mixing time and speed as well as their interaction with hydrophobic agents, especially at high air content levels. A possibility to stabilize the air content in renovation render is to use Poraver
In our research we wanted to find out if Poraverrated with salt according to ?WTA Merkblatt 2-9-04/D? for renovation mortar systems. From those prisms small samples were cut approx. 0.5 cm below the surface with efflorescence. The samples were freed from dust by means of compressed air and sputtered with gold.
Analysis
SEM (scanning electron microscope) pictures of different areas were prepared and the chemical composition at different points were determined by EDX (energy dispersive X-ray spectroscopy) measurements. Those pictures show particles inside the pores of Poraver
Conclusions
Salt cannot only crystallize in air pores of a renovation render but also in the pores of a lightweight aggregate as long as the pore diameter is big enough and the pore system is open to the surface. Poraver
Further information:
You can request our non-binding formulation for renovation renders here.
Find further information and more pictures here.
Themen in dieser Pressemitteilung:
Unternehmensinformation / Kurzprofil:
Datum: 06.09.2018 - 08:07 Uhr
Sprache: Deutsch
News-ID 1540837
Anzahl Zeichen: 9335
contact information:
Contact person:
Town:
Schlüsselfeld
Phone:
Kategorie:
Mining & Metals
Typ of Press Release:
type of sending:
Date of sending:
Anmerkungen:
Diese Pressemitteilung wurde bisher 440 mal aufgerufen.
Die Pressemitteilung mit dem Titel:
"Application-friendly renovation render with expanded glass
"
steht unter der journalistisch-redaktionellen Verantwortung von
Dennert Poraver GmbH (Nachricht senden)
Beachten Sie bitte die weiteren Informationen zum Haftungsauschluß (gemäß TMG - TeleMedianGesetz) und dem Datenschutz (gemäß der DSGVO).