The new generation of monitoring for modern loads

(PresseBox) - The availability and reliability of power supplies is a decisive factor for the efficiency and productivity of business processes. Unexpected operation interruptions and faults not only cost time and money, they also have a negative impact on production. This means that the early detection of looming interruptions and system faults is top priority in a modern maintenance strategy.
Due to their non-linear power consumption, electrical loads such as PCs, electronic ballasts, copiers, etc. can generate a smooth fault current in modern electrical systems in the event of an error. This requires a complete rethink of protection and monitoring technology. The traditional fault current monitoring devices for alternating and pulsing direct fault currents (type A) used thus far have become unusable in these cases. For this reason, DIN VDE 0100-530 (IEC 60364-5-53) has, for some years, required AC/DC sensitive residual current monitoring.
The reason for this is in the detail: A conventional type A RCM (Residual Current Monitor) would not trigger in the event of a smooth direct error current, as there is no change in magnetisation over time in summation current transformers, and this is required for inductive energy transfer to the RCM trigger relay. Depending on the level, the direct fault current effects an initial magnetisation of the transformer core, thus increasing the RCM trigger threshold for other alternating fault currents which may still be present to the point of not triggering.
The aims of the development of the RCMS150 six-channel residual current monitoring system were varied and ambitious. For good reasons, it needed to be sensitive to all currents for space-sensitive final circuit applications (type B).
With the new RCMS150 residual currents of 0 to 2000 Hz and 0 to 300 mA can be measured and evaluated during operation. The information exchange between the individual type RCMS150 and RCMS460 evaluation devices and a gateway happens via an RS-485 interface. This means that a complete building or a complete supply section (with multiple measurement points and multiple devices) can be permanently monitored from a central point such as a control cabinet or a control room. The history memory and the data logger integrated into the gateway store up to 1000 messages with time stamp.




Further benefits of the RCMS150 are:
adaptation of the internal diameter for residual current measurement in final circuits
simple installation on and behind DIN rails in distribution cabinets
cost-effective version without display, which can be configured via a gateway
compatible with all RCMS460/490 units and gateways installed
Unlike traditional insulation measurement, the RCMS150 offers permanent monitoring of the system and the option to monitor not only cables but also the ?main culprits? in any electrical system - the loads.
It is important that a measurement set up in this way is refined enough to detect damage at an early stage. Monitoring the building feed is very rarely enough. The closer to the final circuit the RCMS technology is installed, the more accurately the fault location and fault currents can be recorded and it becomes clear that the six-channel RCMS150 was developed for exactly this measuring job.

Weitere Infos zu dieser Pressemeldung:

Themen in dieser Pressemitteilung:


Unternehmensinformation / Kurzprofil:



Leseranfragen:



PresseKontakt / Agentur:



drucken  als PDF  an Freund senden  Insulation fault location even more efficient and safe with the new insulation fault location system EDS440
Comfortable insulation monitoring and fault location  with the new insulation monitoring device variant ISOMETER® iso685-D-P
Bereitgestellt von Benutzer: PresseBox
Datum: 01.04.2016 - 03:29 Uhr
Sprache: Deutsch
News-ID 1425344
Anzahl Zeichen: 2768

contact information:
Contact person:
Town:

Grünberg


Phone:

Kategorie:

Research & Development


Typ of Press Release:
type of sending:
Date of sending:
Anmerkungen:


Diese Pressemitteilung wurde bisher 311 mal aufgerufen.


Die Pressemitteilung mit dem Titel:
"RCMS150 residual current monitoring system
"
steht unter der journalistisch-redaktionellen Verantwortung von

Bender GmbH&Co. KG (Nachricht senden)

Beachten Sie bitte die weiteren Informationen zum Haftungsauschluß (gemäß TMG - TeleMedianGesetz) und dem Datenschutz (gemäß der DSGVO).

New, divisible measuring current transformers ...

Bender has added new measuring current transformers to its portfolio that are specifically intended for use in existing electrical installations. The sensors of the CTAS series are divisible and therefore particularly suitable for those installations ...

Bender COMTRAXX?devices ...

The devices of the COMTRAXX? family from Bender GmbH & Co. KG are now even more flexible. With the latest software update, the PROFINET interface has been integrated. It has become the leading standard on the market in recent years. The devices t ...

Electrical safety and high-quality medical technology ...

The Grünberg-based company Bender, specialising in electrical safety, will in future offer medical technology from the Finnish manufacturer Merivaara. Bender expands its hospital portfolio as Merivaara s exclusive sales partner for Germany in order ...

Alle Meldungen von Bender GmbH&Co. KG



 

Who is online

All members: 10 565
Register today: 0
Register yesterday: 2
Members online: 0
Guests online: 62


Don't have an account yet? You can create one. As registered user you have some advantages like theme manager, comments configuration and post comments with your name.