SG measurement - compact, dynamic and inexpensive

(PresseBox) - Multi-channel strain gauge measurements, such as in the field of structural analysis can be realized compact, dynamic and inexpensive with the new 8 channel module A116.
The new module offers 8 freely configurable input channels for measuring bridges. The connection is made with full and half bridges in 3/4 wire or 5/6 wire to compensate cable influences. But also the connection of single strain gauges in quarter-bridge circuit, the influence of cable resistance by detecting the voltage loss in the cable is dynamically compensated. Thus, measurements with high cable lengths are possible.
For internal bridge completion high-precision 120 ? or 350 ? resistors with a temperature coefficient of only 0.05 ppm / K are used. Temperature fluctuations have thus only a small influence. For every change in resistance in these resistors affects the factor 50 on the measurement result.
A common requirement in multi-channel dynamic structural testing is an extremely good correlation among all channels. The maximum jitter between the measured values e.g. 300 channels is only 100 ns.
The transducer excitation can be set to 2 VDC or 4 VDC. The input range can be optimally adjusted by two measuring ranges (1 mV / V or 5 mV / V) to the signal parameters. Without multiplexer 8 A / D converters provide each with 24-bit resolution for a data rate of 20 kHz per channel. Other features: shunt calibration, digital filter 4th order, min-/max-memory, accuracy class of 0.05.




Themen in dieser Pressemitteilung:


Unternehmensinformation / Kurzprofil:



Leseranfragen:



PresseKontakt / Agentur:



drucken  als PDF  an Freund senden  More power for Q.brixx
test.con 5.0 Studio
Bereitgestellt von Benutzer: PresseBox
Datum: 24.06.2013 - 06:05 Uhr
Sprache: Deutsch
News-ID 1239415
Anzahl Zeichen: 0

contact information:
Contact person:
Town:

Darmstadt


Phone:

Kategorie:

Research & Development


Anmerkungen:


Diese Pressemitteilung wurde bisher 131 mal aufgerufen.


Die Pressemitteilung mit dem Titel:
"Q.series A116 - New dimension in strain gauge measurement
"
steht unter der journalistisch-redaktionellen Verantwortung von

Gantner Instruments Test&Measurement GmbH (Nachricht senden)

Beachten Sie bitte die weiteren Informationen zum Haftungsauschluß (gemäß TMG - TeleMedianGesetz) und dem Datenschutz (gemäß der DSGVO).


Alle Meldungen von Gantner Instruments Test&Measurement GmbH



 

Who is online

All members: 10 565
Register today: 0
Register yesterday: 0
Members online: 0
Guests online: 79


Don't have an account yet? You can create one. As registered user you have some advantages like theme manager, comments configuration and post comments with your name.